Smart Tecar Plus — RET / CET Diathermy + Dual Tripolar RF (Face & Body)
The upgraded Smart Tecar. Full 448 kHz capacitive & resistive (CET/RET) deep-thermal therapy for pain relief and recovery — now with two added tripolar RF handles: a fine 3-pole head for the face and a larger 3-pole head for the body, plus an on-screen body-part selector and four energy levels. One machine for physiotherapy and aesthetic skin-care services.

The Smart Tecar Plus is a professional Tecar (Capacitive and Resistive Energy Transfer) diathermy device for physiotherapy clinics, sports-recovery studios, and medspas. Its 448 kHz radiofrequency generates deep, controllable warmth in the tissue — the basis of Tecar therapy, widely used to support pain relief, circulation and tissue recovery. What makes the Plus different: two additional tripolar RF handles turn the same console into a face-and-body skin-care platform, so one investment covers both your rehab caseload and your aesthetic menu. Below: how it works, what the research on the Tecar/CRET category actually shows (objectively, including its limits), the handles and modes, protocols, contraindications, and the business case.
What's New in the Plus
The standard Smart Tecar delivers CET/RET diathermy through two handpieces plus a tripolar circuit-board handle. The Plus adds two dedicated tripolar RF handles so you can run aesthetic RF skin-care treatments alongside physiotherapy — no second machine required.

Body-Contouring & Skin-Care Applications
The tripolar RF handles make the Smart Tecar Plus a versatile aesthetic tool alongside its physiotherapy role. RF warming is widely used in professional body-contouring, body-slimming and skin-firming programs — a high-margin, repeat-visit service line for spas and medspas.
Body contouring & slimming programs
The body RF handle is commonly used to support body-contouring and slimming-appearance sessions on the abdomen, flanks, thighs and arms, warming the tissue to support local circulation and metabolism.
Cellulite-appearance treatments
RF warming is a common component of programs aimed at improving the appearance of cellulite and skin texture over a course of sessions.
Facial skin firming
The fine 3-small-pole face handle is used for RF skin-care and firming-appearance treatments on the face and neck, supporting a smoother, tighter-looking complexion.
Why Clinics Choose the Smart Tecar Plus
CET + RET dual mode
Capacitive (CET) targets high-water-content soft tissue — dermis, muscle, lymphatic and venous systems. Resistive (RET) reaches denser, deeper tissue — muscles, joints, tendons, ligaments. Two depths from one system.
Dual tripolar RF handles
Added face and body RF handpieces extend the machine into aesthetic skin-care services — the core upgrade of the Plus.
4 energy levels
Athermal, Medium Thermal, Deep Thermal and Manual — from gentle biostimulation to deeper warming, or free adjustment 10–100%.
On-screen body map
Select the treatment area on the 7-inch touchscreen for guided reference settings — faster, more consistent sessions.
Full accessory set
RET & CET handpieces, RET & CET tips, two tripolar RF handles, and a stainless-steel return pad — everything to start on day one.
Compact & portable
10 kg desktop unit in a flight case — moves between rooms and ships safely worldwide.

Product & Operation Video
How Tecar (CET / RET) Therapy Works
Tecar stands for Capacitive and Resistive Energy Transfer — a form of deep thermotherapy (diathermy). The device passes 448 kHz radiofrequency between an active electrode and a return plate, generating heat within the tissue itself rather than on the surface. The two modes target different depths:
- CAP (Capacitive / CET): focuses on soft, high-water-content tissue — dermis, lymphatic and venous systems, and muscle. Works at a shallower depth (~3–5 cm).
- RES (Resistive / RET): acts on denser, lower-water tissue — deep muscle, joints, tendons, ligaments, cartilage and bone. Reaches deeper (~8–10 cm).
- Tripolar RF (Plus handles): delivers radiofrequency warming for aesthetic face and body skin-care sessions.

What the Research Says (Tecar / CRET Category)
The following summarizes peer-reviewed research on Tecar / capacitive-resistive electric transfer (CRET) therapy as a category — not on this specific device. Presented objectively, including its limitations, so your team can set realistic client expectations.
Low back & musculoskeletal pain
- A randomized controlled trial in low back pain found Tecar therapy produced significant improvement by the end of treatment and outperformed laser therapy at 1- and 2-month follow-ups. Other RCTs report benefits for knee osteoarthritis, adhesive capsulitis and chronic low back pain when combined with exercise or manual therapy.
- The honest caveat: a PRISMA systematic review found that CRET alone did not show significant differences versus other electrophysical agents (laser, ozone, cryo-ultrasound) in several conditions, and reviewers repeatedly note variable study quality and a need for more high-quality RCTs.
Sources: LBP RCT vs laser (PMID 28685560); knee OA RCT (Coccetta CA et al., Int J Rehabil Res 2019); CRET systematic review (PRISMA). Best used as part of a broader rehab program.
Tendinopathy & recovery
- A 2026 PRISMA systematic review of RCTs on lateral elbow tendinopathy found Tecar showed no statistically significant between-group difference for pain, while functional (DASH) outcomes favored the intervention. A single-session RCT in chronic stroke survivors found Tecar plus functional massage improved muscle-tone measures versus sham.
Sources: lateral elbow tendinopathy systematic review 2026 (Springer); TECAR + massage RCT (PMC10668938). Effects vary by condition and protocol.
Handles & Energy Modes
| Item | Use |
|---|---|
| RET handpiece | Resistive deep-thermal work on dense tissue (joints, tendons, deep muscle) |
| CET handpiece | Capacitive work on soft, high-water tissue (dermis, muscle, circulation) |
| Tripolar RF — face | 3-small-pole RF head for facial & delicate-area skin-care sessions |
| Tripolar RF — body | 3-big-pole RF head for efficient body RF coverage |
| Return pad | Stainless-steel plate that closes the circuit under the treatment area |
| Energy level | Reference intensity / use |
|---|---|
| Athermal | ~10% — gentle biostimulation, warms the skin layer to support cell activity |
| Medium Thermal | ~30% — supports microcirculation and a rise in local tissue temperature |
| Deep Thermal | ~70% — deeper warming used to support cell repair and recovery |
| Manual | Freely adjustable 10–100% to suit the client and area |
Reference Protocols by Area
Starting-point references drawn from the device's on-screen program and common practice. Adjust to client tolerance and your training — these are reference ranges, not prescriptions.
| Area | Mode | Energy | Time | Course |
|---|---|---|---|---|
| Cervical / neck | CET or RET | Athermal–Medium | 20–30 min | 3–5 sessions, every 3–5 days |
| Shoulder / elbow | RET | Medium–Deep | 20–25 min | 3–5 sessions |
| Lower back / waist | RET | Medium–Deep | 25–30 min | 3–5 sessions |
| Knee / ankle | CET + RET | Medium | 20–25 min | 3–5 sessions |
| Facial skin-care | Tripolar RF (face) | Athermal–Medium | 15–20 min | Per aesthetic program |
| Body skin-care | Tripolar RF (body) | Medium | 20–30 min | Per aesthetic program |
| Body contouring / slimming appearance | Tripolar RF (body) | Medium | 25–30 min | Course of 6–10, spaced weekly |
| Cellulite-appearance program | Tripolar RF (body) | Medium | 20–30 min | Course of 6–10 |

Contraindications & Safety
Do NOT treat the following without specialist clearance
- Pregnancy
- Over the eyes / surrounding area
- Over the heart (myocardium)
- Over the spinal cord or head
- Over the gonads, kidneys or liver
- Blood disorders or coagulation problems
- Patients on anticoagulant therapy
- Thrombosis
- Tumor / malignant disease
- Polyneuropathy
- Growing cartilage in children
- Patients on corticosteroid therapy
- Near large nerve bundles or major blood vessels
- Electronic medical implants (e.g., pacemakers)
- Active infection or open wounds at the site
Technical Specifications
| Performance | |
| Technology | Tecar — Capacitive (CET) & Resistive (RET) Energy Transfer + Tripolar RF |
| RF Frequency | 448 kHz |
| Rated Power | 350 W |
| Energy Levels | Athermal / Medium Thermal / Deep Thermal / Manual (10–100%) |
| On-screen Body Selector | Cervical, shoulder, elbow, waist, knee, foot/ankle & more |
| Handles & Hardware | |
| Handpieces | RET + CET + 2× Tripolar RF (face & body) |
| Return Pad | Stainless steel |
| Screen | 7-inch touchscreen |
| Physical & Power | |
| Rated Voltage | AC 110–220V |
| Net Weight | 10 kg |
| Gross Weight | 20 kg |
| Product Size (W×D×H) | 45 × 47.5 × 19 cm |
| Package | Flight case 60 × 51 × 42 cm |
| Compliance & Support | |
| Certification | CE + RoHS |
| Warranty | 2 years (main unit); accessories 6 months |
| Shipping | Free worldwide (DHL / FedEx / UPS); DDP available |
The Business Case
At $1,999, the Smart Tecar Plus earns from two service lines at once. Tecar physiotherapy sessions commonly retail at $60–$150, and RF face/body skin-care sessions at $80–$200 — often sold in courses of several sessions.
Pricing figures are illustrative market ranges and vary by region and service menu — confirm against your local rates.
Training & Onboarding
Free 1-on-1 online training
Live session covering CET/RET use, the tripolar RF handles, energy levels, the on-screen body selector, and maintenance.
Protocol guidance & manual
Reference protocols by area plus the full operation manual, included with every unit.
Certificate provided
Completion certificate for your records and staff onboarding.
Lifetime support
Email & WhatsApp technical support with 24h response, free for the life of the machine.
What's in the Box
- 1 × Smart Tecar Plus Host
- 1 × RET Handpiece · 1 × CET Handpiece
- 2 × Tripolar RF Handles (3-small-pole face + 3-big-pole body)
- 3 × RET Tips · 3 × CET Tips
- 1 × Stainless-Steel Return Pad
- 1 × Power Cord · 1 × Hex Screwdriver
- 1 × User Manual & Protocol Guide

OEM & Wholesale
Logo customization supported — your brand can be printed on the machine body and start-up screen. Distributor programs and bulk pricing available. Contact us to discuss.
Frequently Asked Questions
How is the Plus different from the standard Smart Tecar?
The Plus adds two tripolar RF handles — a 3-small-pole head for the face and a 3-big-pole head for the body — so the same CET/RET diathermy machine also runs aesthetic RF skin-care treatments. It's a physiotherapy and skin-care machine in one.
What's the difference between CET and RET?
CET (capacitive) targets soft, high-water-content tissue like the dermis, muscle and lymphatic/venous systems at a shallower depth. RET (resistive) reaches denser, deeper tissue — joints, tendons, ligaments and deep muscle. Having both lets you treat superficial and deep targets from one machine.
Can I use it for both physiotherapy and facials?
Yes — that's the point of the Plus. Use the CET/RET handpieces for pain-relief and recovery work, and the tripolar RF handles for face and body skin-care sessions.
Can it be used for body contouring, slimming or cellulite?
Yes. The tripolar RF body handle is commonly used in body-contouring, body-slimming and cellulite-appearance programs, warming the tissue to support circulation and the appearance of a firmer, smoother silhouette over a course of sessions. These are wellness/appearance aesthetic services — not a medical weight-loss treatment — and results vary by individual.
What are the energy levels?
Four: Athermal (~10%), Medium Thermal (~30%), Deep Thermal (~70%), and Manual (freely adjustable 10–100%). You choose based on the area and the client's comfort.
What does the on-screen body selector do?
You tap the target area (cervical, shoulder, elbow, waist, knee, foot/ankle and more) on the 7-inch touchscreen to load guided reference parameters for that region.
What does Tecar therapy help with?
Tecar/CRET is commonly used in physiotherapy to support pain relief, circulation and tissue recovery. Published research shows benefits in several musculoskeletal conditions, often comparable to other physical modalities and strongest alongside exercise — see the Clinical Evidence section for sources.
Who should not be treated?
Avoid use with pregnancy; over the eyes, heart, spinal cord, head, gonads, kidneys or liver; with blood-clotting disorders or anticoagulants; thrombosis; tumors; and electronic implants such as pacemakers. See the full contraindications section above and screen every client first.
What certification and warranty does it carry?
CE + RoHS certified, with a 2-year warranty on the main unit (accessories 6 months), free training, and free worldwide shipping (DDP available). Email/WhatsApp support for the life of the machine.
Questions Before You Buy?
Talk to us directly — we're the manufacturer, not a reseller.
📞 +1 310 403 0133 · ✉️ sophia@kmslaser.com · 🌍 buynewbelldeals.com